"MixRite" Dosing Pumps

MixRite Proportioning Water Pump Proportioning Water Pump

The MixRite range of Water Powered Self Priming Dosing Pumps is designed for the accurate injection of a wide variety of liquid additives into water and other liquids used in both agriculture and industry.

Applications

  • Fertilisers
  • Vitamins
  • Fertigation
  • Disinfectants
  • Medicines
  • Water Treatment
  • Supplementation
  • Detergents & Soaps
MixRite Advantages and Specifications
  • Easily installed into water-line
  • Easy to set up, operate and maintain
  • No electricity required - operated solely by water pressure 
  • Automatic self-priming
  • Unaffected by variations in flow or pressure
  • Works with minimal pressure loss and accuracy
  • External adjustment - no contact between you and the chemical solution
  • Strong plastic construction with high chemical resistance
  • High resistance to U.V. radiation
  • Environmentally friendly - reduces the risk of pollution through over concentration of fertilisers
  • Reduces additive wastage - apply exactly the right dose, when and where it is needed.
  • Maximum suction lift is 10 feet
  • Operating Temperature: +4ºC to +40ºC
Dosing Pumps
Air Release Valve system
Allows trapped air to escape.  This air release is accompanied by a slight loss of water

Manual On/Off System
On - Turn the MixRite unit On and allow free flow of water through the unit with the liquid added.
Off - Turn the MixRite unit Off and allow free flow of water only through the unit.

By-Pass system
Pumped additive flows through by-pass pipe connected to the water line without passing through the water engine.

2502

2502
TF5

TF5

TF10

TF10

 

TF25

TF25

Model Adjustable Dosage % Flow Rate Pressure Standard Specifications Inlet x Outlet Part No.
Litre/Hour Gals/Hour Bar PSI
2502 0.2-2 20-2500 4.3-550 0.2-6 2.9-85 Air Release ¾"M TEF02502
2504 0.4-4 20-2500 4.3-550 0.2-6 2.9-85 Air Release ¾"M TEF02504
2510 3-10 50-2500 11-550 0.2-6 7-85 Air Release ¾"M TEF02510
2512 0.2-2 50-2500 11-550 0.4-6 5.8-85 By-Pass with Air Release ¾"M TEF02512
12502 0.2-2 20-2500 4.3-550 0.2-6 2.9-8 On/Off ¾"M TEF12502
12504 0.4-4 20-2500 4.3-550 0.2-6 2.9-85 On/Off ¾"M TEF12504
TF5-001* 0.1-1 200-5000 48-1320 1-8 14.7-120 Air Release 1"M TEF05001
TF5-002* 0.2-2 200-5000 48-1320 1-8 14.7-120 Air Release 1"M TEF05002
TF5-005* 0.5-5 200-5000 48-1320 1-8 14.7-120 Air Release 1"M TEF05005
TF10-002** 0.2-2.5 500-10000 110-2200 1-8 14.7-120 Air Release 1½"M TEF10002
TF10-005** 1-5 500-10000 110-2200 1-8 14.7-120 Air Release 1½"M TEF10005
TF25-002** 0.2-2.5 2000-25000 440-5500 1-8 14.7-120 Air Release 63mm PE TEF25002
TF25-005** 1-5 2000-25000 440-5500 1-8 14.7-120 Air Release 63mm PE TEF25005
* TF5 has an integral anti-siphon valve.
* TF5 can also be supplied with the manual on/off system if required - price for this is available on request.
** TF25 Unit comes complete with steel stand. A stand for the TF10 can be supplied on request at extra cost.