Priming Devices |
| Automatic
Priming Pump
Super Primer
- Primer powered by a 12
volt supply (10.8 amp)
- Primes a vertical
4" x 20 foot suction pipe in 2 minutes
- Timer switch enables
you to check for suction leaks while priming
- Flow switch to switch
unit off when the pump is primed
- Automatic drain valve.
- Reduces pump wear and
gland packing failure that can occur with engine exhaust/manifold
powered priming systems
- Flow: 0"
vacuum = 58 litres/min. - 20" vacuum = 8.3 litres/min.
- Maximum vacuum =
22" of mercury
|
 |
| How It Works
The valve is opened on the irrigation
pump and the timer switch is turned on (e.g. for 5 minutes).
The exhaust flap should be pressed firmly until vacuum holds it in
place. When primed, water enters the Super Primer tank. Close
the valve on the irrigation pump and switch off timer. If the pump
primes when unattended, the internal float switch will automatically shut
off the Super Primer. Ensure the valve on the irrigation pump is
closed before starting the engine. |
Exhaust
Primer
- Fitted to the exhaust pipe on diesel
engine pump units
- Uses the engine exhaust to operate a
venturi mechanism to automatically prime the irrigation pumps suction
pipe
- Once primed it is disengaged, ready
for use next time
- Standard or lever operated
|

|
Manual
Priming Pump
- Mounted on a centrifugal pump, allows
priming in seconds
- Considerable capacity enables priming
operation to be carried out quickly
|

|
|
For
more information & prices please
< Contact Us > |